Related Experiment Video
Updated: Aug 16, 2025

Making, Testing, and Using Potassium Ion Selective Microelectrodes in Tissue Slices of Adult Brain
Published on: May 7, 2018
One-step rapid colorimetric detection of K+ using silver nanoparticles modified by crown ether
Yufeng Sun1,2,3, Shengwen Wang2, Fangfang Wang2
1Faculty of Materials, Metallurgical and Chemistry, Jiangxi University of Science and Technology, Ganzhou 341000, China. hweiya@126.com.
Abstract:
Urinary potassium is an important parameter in clinical health diagnosis. Rapid and convenient detection of potassium ions (K+) in urine is essential for personal healthcare and health management. Here, crown ether (4-aminodibenzo-18-crown-6, ADC) modified silver nanoparticles (ADC-Ag NPs) were successfully prepared for one-step rapid colorimetric detection of urinary potassium. The detection mechanism is as follows: due to the matching sizes of the diameter of K+ and the cavity in crown ether 6, K+ is encapsulated between the cavities of two crown ethers, resulting in the clumping of ADC-Ag NPs and the color of the solution being altered. The colorimetric detection method has a fast response and is completed within 20 minutes. It also shows good selectivity and interference immunity. The lowest detectable concentration is 20 μM with the naked eye and 2.16 μM for UV-vis absorption spectroscopy. A good linear relationship (R2 = 0.9931) between the absorption intensity ratio and K+ concentration (0-100 μM) indicates that this colorimetric probe can be used to detect K+. The method was also applied for quantitative analysis of K+ in real urine samples with recovery between 116 and 120%.
More Related Videos
10:59Use of Label-free Optical Biosensors to Detect Modulation of Potassium Channels by G-protein Coupled Receptors
Published on: February 10, 2014
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...