Related Experiment Video
Updated: Aug 16, 2025

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
Intramolecular hydrogen bond-tuned thermal-responsive carbon dots and their application to abnormal body temperature
Chan Wang1, Yimin He1, Jianfeng Huang2
1Key Laboratory of Synthetic and Biological Colloids, Ministry of Education, International Joint Research Center for Photoresponsive Molecules and Materials, School of Chemical & Material Engineering, Jiangnan University, Wuxi 214122, China.
Abstract:
A steric hindrance strategy was used to prepare intramolecular hydrogen bond-controlled thermosensitive fluorescent carbon dots (CDs) via the solvothermal treatment of o-phenylenediamine respectively with three dihydroxybenzene isomers. The CDs obtained from different isomers have very similar morphology, surfaces, and photophysical properties but exhibited different thermal sensitivities. Meanwhile, the orange-emitting CDs (p-CDs) obtained from o-phenylenediamine and p-hydroquinone exhibited an optimal thermal sensitivity of 1.1%/°C. Comprehensive experimental characterizations and theoretical calculations revealed that even a small difference in substituent locations in the phenyl ring of the precursors can considerably affect the formation of intramolecular hydrogen bonds and that the CDs with strong intramolecular hydrogen bonds exhibited poor thermosensitivity. The p-CDs were incorporated with reference CDs (B-CDs) that exhibited heating-quenching blue emission through electrostatic self-assembly to construct a dual-emission probe (p-CDs/B-CDs), which exhibited a thermal sensitivity of 2.0%/°C. Test strips based on the p-CDs/B-CDs were prepared to measure temperature fluctuations based on sensitive and instant fluorescence color evolution. Further, this fluorescent colorimetry was successfully applied to a test strip-integrated wearable wristband to measure the body temperature. This study establishes an inherent relationship between precursors and the resulting intramolecular hydrogen bonds for precisely tuning the thermal sensitivity of CDs. It also offers a visual quantitative strategy for the early warning of abnormal body temperatures.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermosensation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Body Temperature

