Aims:
Our goal was to evaluate a previously validated artificial intelligence-augmented electrocardiography (AI-ECG) screening tool for left ventricular systolic dysfunction (LVSD) in patients undergoing high-sensitivity-cardiac troponin T (hs-cTnT).
Methods And Results:
Retrospective application of AI-ECG for LVSD in emergency department (ED) patients undergoing hs-cTnT. AI-ECG scores (0-1) for probability of LVSD (left ventricular ejection fraction ≤ 35%) were obtained. An AI-ECG score ≥0.256 indicates a positive screen. The primary endpoint was a composite of post-discharge major adverse cardiovascular events (MACEs) at two years follow-up. Among 1977 patients, 248 (13%) had a positive AI-ECG. When compared with patients with a negative AI-ECG, those with a positive AI-ECG had a higher risk for MACE [48 vs. 21%, P < 0.0001, adjusted hazard ratio (HR) 1.39, 95% confidence interval (CI) 1.11-1.75]. This was largely because of a higher rate of deaths (32 vs. 14%, P < 0.0001; adjusted HR 1.26, 95% 0.95-1.66) and heart failure hospitalizations (26 vs. 6.1%, P < 0.001; adjusted HR 1.75, 95% CI 1.25-2.45). Together, hs-cTnT and AI-ECG resulted in the following MACE rates and adjusted HRs: hs-cTnT < 99th percentile and negative AI-ECG: 116/1176 (11%; reference), hs-cTnT < 99th percentile and positive AI-ECG: 28/107 (26%; adjusted HR 1.54, 95% CI 1.01-2.36), hs-cTnT > 99th percentile and negative AI-ECG: 233/553 (42%; adjusted HR 2.12, 95% CI 1.66, 2.70), and hs-cTnT > 99th percentile and positive AI-ECG: 91/141 (65%; adjusted HR 2.83, 95% CI 2.06, 3.87).
Conclusion:
Among ED patients evaluated with hs-cTnT, a positive AI-ECG for LVSD identifies patients at high risk for MACE. The conjoint use of hs-cTnT and AI-ECG facilitates risk stratification.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System V: CT