Related Experiment Video
Updated: Aug 16, 2025

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
Feasibility of Modified Endobronchial Ultrasound-Guided Intranodal Forceps Biopsy: A Retrospective Analysis
Aya Konno-Yamamoto1,2,3, Yuji Matsumoto4,5, Tatsuya Imabayashi4
1Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan, ayakonno-tjo@umin.ac.jp.
Background:
Endobronchial ultrasound (EBUS)-guided intranodal forceps biopsy (IFB), a diagnostic bronchoscopic technique for intrathoracic lymphadenopathy, is performed following EBUS-guided transbronchial needle aspiration (TBNA). The current EBUS-IFB technique is complex and provides small sample volumes. We modified this technique to allow the use of standard-sized forceps.
Objectives:
The aim of this study was to assess the feasibility of the modified EBUS-IFB technique, which combines standard-sized forceps with standard EBUS-TBNA equipment.
Method:
This retrospective analysis included consecutive patients scheduled for EBUS-TBNA with attempted additional IFB between July 2020 and March 2021. The feasibility indices of IFB, technical success rate, diagnostic accuracy, and major complications were retrospectively investigated. We performed semi-quantitative evaluation of the histological specimens and univariable analyses to identify factors associated with IFB failure.
Results:
During the study period, 295 patients underwent 307 EBUS-TBNAs; 195 cases were included in the analyses. Target lesions were mainly mediastinal lymph nodes (134 cases, 68.7%); the most frequent sites were #7 (61 cases) and #4R (50 cases). The median lesion size was 16.1 mm, the technical IFB success rate was 90.8%, and the diagnostic accuracy of the TBNA and IFB combination was 99.5%. One patient was lost to follow-up. Univariable analyses did not identify any factors involved in technical IFB failure. Major complications of pneumonia and pneumothorax occurred in 2 cases (1.0%). The median histological score was significantly higher in the IFB group than in the TBNA group (1.67 vs. 1.50, p = 0.032).
Conclusions:
Modified EBUS-IFB, combining standard-sized forceps with common EBUS-TBNA equipment, is feasible with few major complications.
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...