Related Experiment Video
Updated: Aug 16, 2025

Author Spotlight: Traditional Chinese Medicine for Sleep Disorders in Acute COPD — A Safe, Cost-Effective Approach
Published on: October 18, 2024
Nasal polyposis is a risk factor for nonadherence to CPAP treatment in sleep apnea: the population-based DISCOVERY
Caroline Bengtsson1, Ludger Grote2,3, Mirjam Ljunggren4
1Department of Surgical Sciences, Otorhinolaryngology, Head and Neck Surgery, Uppsala University, Uppsala, Sweden.
Study Objectives:
The aim was to evaluate nasal polyposis as a risk factor for nonadherence to continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnea (OSA).
Methods:
This was a population-based, longitudinal analysis of patients starting CPAP treatment for OSA in the Swedish quality registry Swedevox between 2010 and 2018. Data were cross-linked with national registries. The impact of nasal polyposis on CPAP adherence was analyzed using uni- and multivariable logistic and linear regression models. Relevant confounders (age, sex, usage of nasal and oral steroids) were identified using a direct acyclic graph.
Results:
Of 20,521 patients with OSA on CPAP treatment (29.5% females), 331 (1.6%) had a diagnosis of nasal polyposis at baseline. At the 1-year follow-up, nasal polyposis was associated with an increased risk of CPAP usage < 4 hours/night (unadjusted odds ratio [OR] 1.21; 95% confidence interval [CI] 0.95-1.55); adjusted OR 1.38; 95% CI 1.08-1.77). In this group, unadjusted nocturnal mean CPAP usage was 15.4 minutes (95% CI -31.62 to 0.83) shorter and was an adjusted 24.1 minutes (95% CI -40.6 to -7.7) shorter compared with patients with OSA without nasal polyposis.
Conclusions:
Nasal polyposis is associated with reduced CPAP usage per night. These results highlight the importance of diagnosing nasal polyposis in patients with OSA before the start of CPAP treatment. Treatment of the condition may improve adherence, efficacy, and patient outcomes.
Citation:
Bengtsson C, Grote L, Ljunggren M, Ekström M, Palm A. Nasal polyposis is a risk factor for nonadherence to CPAP treatment in sleep apnea: the population-based DISCOVERY study. J Clin Sleep Med. 2023;19(3):573-579.
More Related Videos
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Suctioning the Nasopharyngeal Airway
Equipment Required
Chronic Obstructive Pulmonary Disease-V: Nursing Management
Assessment
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation

