Background: Arterial stiffness, measured by pulse wave velocity (PWV), is a purported mechanism linking sedentary behavior to cardiovascular disease. This secondary analysis compared associations between measured carotid−femoral PWV (cfPWV) and carotid−radial (crPWV) responses to an acute bout of prolonged sitting with mathematically estimated cfPWV (ePWV). Methods: Overweight/obese adults with elevated blood pressure were enrolled (n = 25; 42 ± 12 yrs; 64% males). Participants performed an 8 h simulated workday of mostly sitting. cfPWV and crPWV were measured while supine in the morning, midday, and afternoon. ePWV was calculated at the same timepoints using age and seated mean arterial pressure (MAP). Pearson correlation coefficients associated ePWV with cfPWV and crPWV. Generalized linear models separately examined the effects of time on cfPWV, crPWV, and ePWV. Results: ePWV significantly associated with cfPWV and crPWV (r = 0.69 and 0.55, respectively; p < 0.05) in the morning (baseline). cfPWV significantly increased over time (β = 0.52 ± 0.20 and 0.48 ± 0.21 with and without MAP adjustment, respectively; p < 0.05). In contrast, ePWV and crPWV did not significantly increase overtime (β = 0.14 ± 0.09 and 0.25 ± 0.23, respectively; p > 0.05). Conclusions: Our results suggest that, although ePWV is associated with cfPWV and crPWV at a fixed timepoint, ePWV responds differently to prolonged sitting and likely does not capture the same acute vascular responses.
Related Concept Videos
Pulse
The pulse serves as a clinical...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse Assessment Sites
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.