A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
Minimizing Specific Energy Consumption of Electrochemical Hydrogen Compressor at Various Operating Conditions Using
Changhyun Kim1, Myungkeun Gong1, Jaewon Lee1
1Department of Mechanical and Information Engineering, University of Seoul, Seoul 02504, Republic of Korea.
Abstract:
With the increased usage of hydrocarbon-based fossil fuels, air pollution and global warming have accelerated. To solve this problem, renewable energy, such as hydrogen technology, has gained global attention. Hydrogen has a low volumetric density and thus requires compression technologies at high pressures to reduce storage and transportation costs. Techniques for compressing hydrogen include using mechanical and electrochemical hydrogen compressors. Mechanical compressors require higher specific energy consumption than electrochemical hydrogen compressors. Here, we used an electrochemical hydrogen compressor as a pseudo-two-dimensional model focused on electroosmotic drag, water back-diffusion, and hydrogen crossover flux at various temperatures, polymer electrolyte membrane thicknesses, and relative humidity conditions. To date, there have been few studies based on various operating conditions to find the optimal conditions. This study was conducted to determine the optimal parameters under various operating conditions. A numerical analysis demonstrated that the specific energy consumption was low in a specific current density section when the temperature was decreased. At the above-mentioned current density, the specific energy consumption decreased as the temperature increased. The polymer electrolyte membrane thickness yielded similar results. However, according to the relative humidity, it was confirmed that the higher the relative humidity, the lower the specific energy consumption in all of the current density sections. Therefore, when comparing temperatures of 30 °C and 80 °C at 145 A/m2, operating at 30 °C reduces the specific energy consumption by 12.12%. At 3000 A/m2 and 80 °C, the specific energy consumption is reduced by 11.7% compared to operating at 30 °C. Using N117 compared to N211 at 610 A/m2 for polymer electrolyte membranes can reduce specific energy consumption by 10.4%. Using N211 in the 1500 A/m2 condition reduces the specific energy demand by 9.6% compared to N117.
More Related Videos
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
08:59Modeling and Experimental Analysis of the Single-Shaft Coaxial Motor-Pump Assembly in Electrohydrostatic Actuators
Published on: June 13, 2022
Related Concept Videos
Energy Conservation and Bernoulli's Equation
All the terms in the equation have the dimension of energy per unit volume. The kinetic energy per unit volume is called the kinetic energy density, and the potential energy per unit volume is...
Typical Model Studies
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...