Applying ZCT to Two-Phase Boost Converter with IGBT Switches Used

Kuo-Ing Hwu1, Pei-Ching Tseng1

  • 1Department of Electrical Engineering, National Taipei University of Technology, 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan.

Micromachines
|December 23, 2022
PubMed

Related Concept Videos

Switching of BJT01:22

Switching of BJT

Switching behavior in Bipolar Junction Transistors (BJTs) is a fundamental aspect utilized in various electronic circuits, particularly for digital logic applications like switches and amplifiers. In a typical switching circuit, a BJT alternates between cut-off and saturation modes, corresponding to the "off" and "on" states, respectively, thus behaving like an ideal switch.
Cut-off Mode ("Off" State): In this state, both the emitter-base and collector-base junctions are...
483
Bipolar Junction Transistor01:22

Bipolar Junction Transistor

Bipolar Junction Transistors (BJTs) are essential elements in electronic circuits, playing a crucial role in the functionality of amplifiers, memories, and microprocessors. These transistors can be designed as NPN or PNP based on their doping patterns. They consist of three layers: the emitter, base, and collector. The configuration of these layers and their respective doping levels—with N-type or P-type impurities—define the transistor's type and its operational...
859
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
156
The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
701
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
141
Three-Phase Circuits01:22

Three-Phase Circuits

AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
461