Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Overview of Microscopy Techniques01:22

Overview of Microscopy Techniques

10.6K
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...
10.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Advances in iridium single-atom catalysts for the electrochemical oxygen evolution reaction.

Chemical communications (Cambridge, England)·2026
Same author

Direct reduction of CO<sub>2</sub>catalyzed by a formate dehydrogenase immobilized on carbon nanotubes without NADH cofactor.

Nanotechnology·2026
Same author

<i>In Situ</i> Monitoring of Hypochlorite Decay under Radiation Using Differential Pulse Voltammetry.

ACS electrochemistry·2026
Same author

Recent advances in carbon-based quantum dots for sensing applications.

Nanoscale·2025
Same author

Photobasicity-Triggered Twisted Intramolecular Charge Transfer of Push-Pull Chromophores.

The journal of physical chemistry. B·2025
Same author

Sensitive Electrochemical Determination of Vanillin Using a Bimetallic Hydroxide and Reduced Graphene Oxide Nanocomposite.

Sensors (Basel, Switzerland)·2025

Related Experiment Video

Updated: Aug 16, 2025

Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope AFM-SECM
08:31

Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope AFM-SECM

Published on: February 10, 2021

6.9K

Micro-Sized pH Sensors Based on Scanning Electrochemical Probe Microscopy.

Muhanad Al-Jeda1, Emmanuel Mena-Morcillo1, Aicheng Chen1

  • 1Electrochemical Technology Center, Department of Chemistry, University of Guelph, 50 Stone Road East, Guelph, ON N1G 2W1, Canada.

Micromachines
|December 23, 2022
PubMed
Summary

Micro/nano pH sensors offer high spatial resolution for monitoring surface processes. Scanning electrochemical microscopy (SECM) enhances their application in diverse scientific fields.

Keywords:
localized pHmicroelectrode probemicrosensornanosensorpotentiometric sensorscanning electrochemical microscopyvoltammetric sensor

More Related Videos

Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
09:15

Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors

Published on: November 22, 2016

10.7K
Scanning-probe Single-electron Capacitance Spectroscopy
10:53

Scanning-probe Single-electron Capacitance Spectroscopy

Published on: July 30, 2013

13.1K

Related Experiment Videos

Last Updated: Aug 16, 2025

Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope AFM-SECM
08:31

Probing Surface Electrochemical Activity of Nanomaterials using a Hybrid Atomic Force Microscope-Scanning Electrochemical Microscope AFM-SECM

Published on: February 10, 2021

6.9K
Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
09:15

Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors

Published on: November 22, 2016

10.7K
Scanning-probe Single-electron Capacitance Spectroscopy
10:53

Scanning-probe Single-electron Capacitance Spectroscopy

Published on: July 30, 2013

13.1K

Area of Science:

  • Electrochemistry
  • Materials Science
  • Analytical Chemistry

Background:

  • Understanding surface processes requires monitoring pH at the micro/nano scale.
  • Micro/nano-sized pH sensors are crucial for detecting local pH changes at interfaces.
  • Scanning electrochemical microscopy (SECM) enables high spatial resolution measurements.

Purpose of the Study:

  • To review the design, fabrication, and applications of micro/nano-sized pH sensors with SECM.
  • To examine probe selection for biological, corrosion, energy, and environmental studies.
  • To summarize and compare different types of pH-sensitive probes.

Main Methods:

  • Review of state-of-the-art micro/nano-pH sensor design and fabrication.
  • Integration of pH sensors with Scanning Electrochemical Microscopy (SECM).
  • Comparative analysis of various pH-sensitive probe types.

Main Results:

  • Detailed examination of micro/nano-pH sensor applications in diverse fields.
  • Considerations for probe selection based on specific research areas.
  • Summary and comparison of existing pH sensing probe technologies.

Conclusions:

  • Micro/nano-pH sensors coupled with SECM are powerful tools for surface process analysis.
  • The review provides insights into probe selection and future trends.
  • Emerging applications highlight the growing importance of nanoscale pH monitoring.