Solid Sampling Pyrolysis Adsorption-Desorption Thermal Conductivity Method for Rapid and Simultaneous Detection of N
Derong Shang1, Wenyan Gu1, Yuxiu Zhai1
1Key Laboratory of Testing and Evaluation for Aquatic Product Safety and Quality, Ministry of Agriculture and Rural Affairs, Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071, China.
Abstract:
In this work, a rapid method for the simultaneous determination of N and S in seafood was established based on a solid sampling absorption-desorption system coupled with a thermal conductivity detector. This setup mainly includes a solid sampling system, a gas line unit for controlling high-purity oxygen and helium, a combustion and reduction furnace, a purification column system for moisture, halogen, SO2, and CO2, and a thermal conductivity detector. After two stages of purging with 20 s of He sweeping (250 mL/min), N2 residue in the sample-containing chamber can be reduced to <0.01% to improve the device’s analytical sensitivity and precision. Herein, 100 s of heating at 900 °C was chosen as the optimized decomposition condition. After the generated SO2, H2O, and CO2 were absorbed by the adsorption column in turn, the purification process executed the vaporization of the N-containing analyte, and then N2 was detected by the thermal conductivity cell for the quantification of N. Subsequently, the adsorbed SO2 was released after heating the SO2 adsorption column and then transported to the thermal conductivity cell for the detection and quantification of S. After the instrumental optimization, the linear range was 2.0−100 mg and the correlation coefficient (R) was more than 0.999. The limit of detection (LOD) for N was 0.66 μg and the R was less than 4.0%, while the recovery rate ranged from 95.33 to 102.8%. At the same time, the LOD for S was 2.29 μg and the R was less than 6.0%, while the recovery rate ranged from 92.26 to 105.5%. The method was validated using certified reference materials (CRMs) and the measured N and S concentrations agreed with the certified values. The method indicated good accuracy and precision for the simultaneous detection of N and S in seafood samples. The total time of analysis was less than 6 min without the sample preparation process, fulfilling the fast detection of N and S in seafood. The establishment of this method filled the blank space in the area of the simultaneous and rapid determination of N and S in aquatic product solids. Thus, it provided technical support effectively to the requirements of risk assessment and detection in cases where supervision inspection was time-dependent.
More Related Videos
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...