Related Experiment Video
Updated: Aug 16, 2025

Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
Published on: June 9, 2016
Range-resolved detection of boundary layer stable water vapor isotopologues using a ground-based 1.98 µm differential
Abstract:
This paper presents a first demonstration of range-resolved differential absorption LIDAR (DIAL) measurements of the water vapor main isotopologue H2 16O and the less abundant semi-heavy water isotopologue HD16O with the aim of determining the isotopic ratio. The presented Water Vapor and Isotope Lidar (WaVIL) instrument is based on a parametric laser source emitting nanosecond pulses at 1.98 µm and a direct-detection receiver utilizing a commercial InGaAs PIN photodiode. Vertical profiles of H2 16O and HD16O were acquired in the planetary boundary layer in the suburban Paris region up to a range of 1.5 km. For time averaging over 25 min, the achieved precision in the retrieved water vapor mixing ratio is 0.1 g kg-1 (2.5% relative error) at 0.4 km above ground level (a.g.l.) and 0.6 g kg-1 (20%) at 1 km a.g.l. for 150 m range bins along the LIDAR line of sight. For HD16O, weaker absorption has to be balanced with coarser vertical resolution (600 m range bins) in order to achieve similar relative precision. From the DIAL measurements of H2 16O and HD16O, the isotopic abundance δD was estimated as -51‰ at 0.4 km above the ground and -119‰ in the upper part of the boundary layer at 1.3 km a.g.l. Random and systematic errors are discussed in the form of an error budget, which shows that further instrumental improvements are required on the challenging path towards DIAL-profiling of the isotopic abundance with range resolution and precision suitable for water cycle studies.
More Related Videos
13:27Exploring the Effects of Atmospheric Forcings on Evaporation: Experimental Integration of the Atmospheric Boundary Layer and Shallow Subsurface
Published on: June 8, 2015
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Related Concept Videos
Boundary Layer Characteristics
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Atomic Absorption Spectroscopy: Atomization Methods
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
UV–Vis Spectroscopy: Beer–Lambert Law
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...