Simultaneous reception of AMCC signals and QPSK signals by a single coherent receiver with DSP

Optics Express
|December 23, 2022
PubMed

Related Concept Videos

Aliasing01:18

Aliasing

Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
192
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
262
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
283
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
310
Cascaded Op Amps01:16

Cascaded Op Amps

Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
692
Sampling Continuous Time Signal01:11

Sampling Continuous Time Signal

In signal processing, a continuous-time signal can be sampled using an impulse-train sampling technique, followed by the zero-order hold method. Impulse-train sampling involves the use of a periodic impulse train, which consists of a series of delta functions spaced at regular intervals determined by the sampling period. When a continuous-time signal is multiplied by this impulse train, it generates impulses with amplitudes corresponding to the signal's values at the sampling points.
In the...
324