Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve
Cyrus Tanade1, S James Chen2, Jane A Leopold3
1Department of Biomedical Engineering, Duke University, Durham, NC, United States.
Background:
Personalized hemodynamic models can accurately compute fractional flow reserve (FFR) from coronary angiograms and clinical measurements (FFR ), but obtaining patient-specific data could be challenging and sometimes not feasible. Understanding which measurements need to be patient-tuned vs. patient-generalized would inform models with minimal inputs that could expedite data collection and simulation pipelines.
Aims:
To determine the minimum set of patient-specific inputs to compute FFR using invasive measurement of FFR (FFR ) as gold standard.
Materials And Methods:
Personalized coronary geometries ( ) were derived from patient coronary angiograms. A computational fluid dynamics framework, FFR , was parameterized with patient-specific inputs: coronary geometry, stenosis geometry, mean arterial pressure, cardiac output, heart rate, hematocrit, and distal pressure location. FFR was validated against FFR and used as the baseline to elucidate the impact of uncertainty on personalized inputs through global uncertainty analysis. FFR was created by only incorporating the most sensitive inputs and FFR additionally included patient-specific distal location.
Results:
FFR was validated against FFR via correlation ( , ), agreement (mean difference: ), and diagnostic performance (sensitivity: 89.5%, specificity: 93.6%, PPV: 89.5%, NPV: 93.6%, AUC: 0.95). FFR provided identical diagnostic performance with FFR . Compared to FFR vs. FFR , FFR vs. FFR had decreased correlation ( , ), improved agreement (mean difference: ), and comparable diagnostic performance (sensitivity: 79.0%, specificity: 90.3%, PPV: 83.3%, NPV: 87.5%, AUC: 0.90).
Conclusion:
Streamlined models could match the diagnostic performance of the baseline with a full gamut of patient-specific measurements. Capturing coronary hemodynamics depended most on accurate geometry reconstruction and cardiac output measurement.