Retrieval of a fractured implant abutment screw using a microtube extraction device: A dental technique
Kan Zeng1, Yunmei Dong2, Lei Li3
1Graduate student, State Key Laboratory of Oral Diseases, Department of Prosthodontics, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
Abstract:
Abutment screw fracture is a mechanical complication associated with the failure of dental implant-supported restorations. Retrieval of fractured abutment screws without damaging the internal surface of implants is challenging and can be time-consuming. Microtube extraction devices are used to remove separated endodontic instruments. This article presents a conservative method of retrieving a fractured implant abutment screw using a microtube device.