Introduction:
Small bowel obstruction (SBO) due to internal herniation (IH) is a well-known complication of laparoscopic Roux-en-Y gastric bypass (LRYGBP). The objective of this study is to evaluate different types of non-absorbable sutures used for closure of the defects regarding the incidence of SBO due to IH/adhesions, adhesion formation in general, or reopening of the defects.
Methods:
A single-center retrospective study was performed. Patients who underwent LRYGBP were divided in 3 groups: group A closure of the defects with monofilament Polypropylene suture (Prolene®), group B with braided polyester suture (Ethibond®), group C with barbed knotless Polybutester suture (V-Loc®). Descriptive statistics were performed regarding SBO due to IH/adhesions, adhesion formation, and reopening of closed defects.
Results:
From 5145 patients, 224 patients underwent exploratory laparoscopy for suspicion of SBO. Mean time interval was 28.4 months. IH or intermittent IH was found in 1.94% in group A, 1.78% in group B, and 1.40% in group C. Obstruction due to adhesions was found in 0.70%, 0.36%, and 0.42% per group, respectively. Adhesions in general were observed in 1.47% in group A, 1.43% in group B, and 1.06% in group C. The incidence of reopening was higher in group A (2.24%) in comparison with group B (1.13%, P = 0.041) and group C (1.05%, P = 0.001).
Conclusions:
After descriptive analysis, these results can withhold no difference among the 3 non-absorbable sutures regarding incidence of SBO due to IH or SBO due to adhesions, yet tendency for higher reopening rates after closure with monofilament Polypropylene suture is observed.