Related Experiment Video
Updated: Aug 16, 2025

Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Occult Diastolic Dysfunction and Adverse Clinical Outcomes in Adolescents and Young Adults With Fontan Circulation
Daniel Peck1, Konstantin Averin2, Philip Khoury1
1The Heart Institute, Cincinnati Children's Hospital Medical Center Department of Pediatrics University of Cincinnati College of Medicine Cincinnati OH.
Insights
Occult diastolic dysfunction (ODD) in Fontan circulation is detectable via rapid volume expansion. ODD is linked to longer Fontan duration and increased adverse clinical outcomes, especially in patients with longer Fontan circulation history.
Area of Science:
- Cardiology
- Pediatric Cardiology
- Congenital Heart Disease
Background:
- Diastolic dysfunction in Fontan circulation is linked to poor outcomes but often undetected.
- Invasive assessment using rapid volume expansion (RVE) can reveal occult diastolic dysfunction (ODD).
Purpose of the Study:
- To assess the association between ODD and adverse clinical outcomes in patients with Fontan circulation.
- To determine if ODD, identified by RVE, predicts medium-term adverse events.
Main Methods:
- Single-center observational study of 89 Fontan circulation patients undergoing RVE between 2012-2017.
- ODD defined as post-RVE end-diastolic pressure ≥15 mmHg.
- Composite adverse outcome included mortality, transplant, VAD, plastic bronchitis, protein-losing enteropathy, arrhythmia, stroke/thrombus, or cardiac admission.
Main Results:
- ODD was identified in 31% of patients, associated with longer Fontan duration (P=0.001).
- The composite adverse outcome occurred more frequently in the ODD group (52% vs. 26%, P=0.03).
- ODD (HR 2.68, P=0.02) and Fontan duration (HR 1.07, P=0.003) independently predicted adverse outcomes.
Conclusions:
- Cardiac catheterization with RVE effectively identifies ODD in Fontan circulation, correlating with Fontan duration.
- ODD is associated with a significantly increased risk of adverse clinical outcomes in the medium term.
- ODD may serve as a crucial prognostic indicator for patients with Fontan circulation, particularly those with longer Fontan duration.
Abstract:
Background In Fontan circulation, diastolic dysfunction portends a worse clinical outcome but may be concealed during routine assessment. Invasive evaluation with rapid volume expansion (RVE) can identify patients with occult diastolic dysfunction (ODD). We sought to evaluate the association between ODD and adverse clinical outcomes at medium-term follow-up. Methods and Results We conducted a single-center observational study of patients with Fontan circulation who underwent clinical catheterization with RVE from 2012 to 2017. ODD was defined as post-RVE end-diastolic pressure ≥15 mm Hg. A composite adverse clinical outcome included mortality, cardiac transplant, ventricular assist device, plastic bronchitis, protein-losing enteropathy, arrhythmia, stroke/thrombus, or cardiac-related hospital admission. Proportional hazards regression was used to compare the ODD-positive and ODD-negative groups for risk of the composite adverse clinical outcome. Eighty-nine patients with Fontan circulation (47% female patients) were included at a median age of 14 years. ODD was identified in 31%. Fontan duration was longer in the ODD group (P=0.001). The composite adverse clinical outcome occurred more frequently in the ODD group (52 versus 26%, P=0.03) during a median follow-up duration of 2.9 years after catheterization. ODD (hazard ratio [HR], 2.68 [95% CI, 1.28-5.66]; P=0.02) and Fontan duration (HR, 1.07 [95% CI, 1.02-1.12]; P=0.003) were associated with the composite adverse clinical outcome. When stratified by Fontan duration, ODD remained significantly associated with the hazard of adverse clinical outcomes in patients with a Fontan duration ≥10 years (HR, 2.57 [95% CI, 1.03-6.57]; P=0.04). Conclusions Cardiac catheterization with rapid volume expansion reveals a significant incidence of ODD, which relates to Fontan duration. ODD is associated with an increased hazard of adverse clinical outcomes during medium-term follow-up, especially in patients with longer Fontan duration. ODD may portend a worse prognosis in Fontan circulation.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Heart Failure II: Pathophysiology
Mitral Stenosis I: Introduction
Mitral Regurgitation I: Introduction
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management