Related Experiment Video
Updated: Aug 16, 2025

Kinematic History of a Salient-recess Junction Explored through a Combined Approach of Field Data and Analog Sandbox Modeling
Published on: August 5, 2016
A switch from horizontal compression to vertical extension in the Vrancea slab explained by the volume reduction of
Andreea Craiu1, Thomas P Ferrand2,3, Elena F Manea1,4
1National Institute for Earth Physics, Calugareni, 12, Măgurele, Ilfov, Romania.
Abstract:
The Vrancea slab, Romania, is a subducted remnant of the Tethyan lithosphere characterized by a significant intermediate-depth seismicity (60-170 km). A recent study showed a correlation between this seismicity and major dehydration reactions, involving serpentine minerals up to 130 km depth, and high-pressure hydrated talc deeper. Here we investigate the potential link between the triggering mechanisms and the retrieved focal mechanisms of 940 earthquakes, which allows interpreting the depth distribution of the stress field. We observe a switch from horizontal compression to vertical extension between 100 and 130 km depth, where the Clapeyron slope of serpentine dehydration is negative. The negative volume change within dehydrating serpentinized faults, expected mostly sub-horizontal in the verticalized slab, could well explain the vertical extension recorded by the intermediate-depth seismicity. This apparent slab pull is accompanied with a rotation of the main compressive stress, which could favour slab detachments in active subduction zones.
More Related Videos
Related Concept Videos
Wedges
Consider using a wedge to lift a heavy slab. Here, the wedge functions by converting the applied force into a much larger force directed almost perpendicular to the initial force. This...
Expansion and Contraction in Masonry Walls
To...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Deformations in a Transverse Cross Section
As the material stretches, it expands or contracts in orthogonal directions to the load. This phenomenon varies...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...

