Reliability and validity of common hip adduction strength measures: The ForceFrame strength testing system versus the
Ciaran O' Connor1, Martin McIntyre2, Eamonn Delahunt3
1School of Public Health, Physiotherapy & Sports Science, University College Dublin, Dublin, Ireland.
Objectives:
The criterion validity of the sphygmomanometer was evaluated, relative to the Force Frame strength testing system. Test-retest reliability was assessed for both hip adduction and abduction strength.
Design:
Test-retest reliability study and criterion validity study.
Participants:
50 asymptomatic, field-sport athletes.
Main Outcome Measures:
Maximal isometric hip adduction and abduction strength were measured. Interclass correlation coefficient(ICC2,1) with confidence intervals were calculated to evaluate reliability of peak strength values. A Pearson product-moment correlation coefficient(r) was calculated to examine criterion validity of the sphygmomanometer as a measure of force when compared to the ForceFrame.
Results:
Intra-rater reliability for bilateral adduction testing using both ForceFrame and sphygmomanometer values revealed good-excellent reliability for both the 0° (ICC2.1 = 0.87-0.90) and 45° (ICC2.1 = 0.81-0.91) positions. ForceFrame values revealed good-excellent reliability for 0° abduction position and 45° abduction position. A good-moderate relationship (Pearson's r = 0.63) for 0° adduction position, and poor relationship (Pearson's r = 0.40) for 45° adduction position, were found between adduction squeeze values on ForceFrame and sphygmomanometer.
Conclusion:
Excellent reliability in hip adduction squeeze strength testing for both modes. However, there exists a 'good to moderate'-'fair' relationship between the Force Frame and sphygmomanometer.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: