Is it necessary to define new diagnostic reference levels during pandemics like the Covid19-?
Banafsheh Zeinali-Rafsanjani1, Azamalsadat Alavi2, Mehrzad Lotfi1
1Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz, Iran.
Introduction:
This study intended to assess the dose length product (DLP), effective cumulative radiation dose (E.D.), and additional cancer risk (ACR) due to a chest CT scan to detect or follow up the Covid-19 disease in four university-affiliated hospitals that used different imaging protocols. Indeed, this study aimed to examine the differences in decision-making between different imaging centers in choosing chest CT imaging protocols during the pandemic, and to assess whether a new diagnostic reference level (DRL) is needed in pandemic situations.
Methods:
This retrospective study assessed the E.D. of all chest imagings for Covid-19 for six months in four different hospitals in our country. Imaging parameters and DLP (mGy.cm) were recorded. The E.D.s and ACRs from chest CT scans were calculated using an online calculator.
Results:
Thousand-six hundred patients were included in the study. The mean cumulative dose due to chest CT was 3.97 mSv which might cause 2.59 × 10-2 ACR. The mean cumulative E.D. in different hospitals was in the range of 1.96-9.51 mSv.
Conclusions:
The variety of mean E.D.s shows that different hospitals used different imaging protocols. Since there is no defined DRL in the pandemic, some centers use routine protocols, and others try to reduce the dose but insufficiently.In pandemics such as Covid-19, when CT scan is used for screening or follow-up, DLPs can be significantly lower than in normal situations. Therefore, international regularized organizations such as the international atomic energy agency (IAEA) or the international commission on radiological protection (IRCP) should provide new DRL ranges.
More Related Videos
Related Concept Videos
Pneumonia III: Complications and Assessment
Steps in Outbreak Investigation
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Principles of Disease Surveillance
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...