Related Experiment Video
Updated: Aug 16, 2025

Author Spotlight: Enhancing Success of Ultrasound-Guided Neuraxial Anesthesia in Cases with Difficult Anatomy
Published on: January 31, 2025
The Confidence and Accuracy of Medical Students Trained in Ultrasound or Landmarks for Performing Knee Aspiration
Emily R German1, Katelyn A Hogge1, Brooke L Reese1
1Medicine, Edward Via College of Osteopathic Medicine (VCOM) Carolinas, Spartanburg, USA.
Abstract:
Introduction Medical students are trained using anatomical landmarks in order to perform many procedures, such as knee aspirations. With the growing popularity and use of ultrasound, the question arises whether training students with ultrasound instead of landmarks increases their skill. Previous research has shown increased accuracy and confidence in residents who trained with ultrasound compared to landmarks only. No studies to date have analyzed the effect of ultrasound learning versus landmark learning in medical students. Objective The purpose of this study is to analyze the confidence and accuracy of medical students when taught knee aspiration using ultrasound training compared to students taught with landmarks only. Methods The project was deemed exempt by the Edward Via College of Osteopathic Medicine (VCOM) Institutional Review Board (IRB) because it falls under the quality improvement category (IRB number 1806802-1). Subjects were randomized into two groups: one trained in ultrasound and one trained in landmarks for performing knee aspirations. Both groups were tested for accuracy by the ability to aspirate fluid from the model and the number of attempts; each student was given a maximum of three attempts. Documentation included the number of attempts for each student or "no fluid" for those exceeding three attempts. They were then surveyed for confidence. The study took place in an educational setting at VCOM-Carolinas. A total of 42 first-year medical students participated in this study. Results Fisher's exact test showed statistically significant results for confidence (p<0.001) between the ultrasound group (N=22) and non-ultrasound group (N=20) with a power of 0.285. The accuracy of aspirating fluid was not found to be statistically significant (p=0.4805). Conclusions Although no significant differences in the accuracy of knee aspirations at short term were seen, there was a clear improvement in student confidence and perceived capability of the skill. Those students who learned using ultrasound-guided techniques were more confident in their ability to accurately perform the technique when compared to their peers.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...

