Related Experiment Video
Updated: Aug 16, 2025

Selected Reaction Monitoring Mass Spectrometry for Absolute Protein Quantification
Published on: August 17, 2015
The Origin-Adjusted Approach for Reliable Quantification of Endogenous Analytes in Mass Spectrometric Bioanalysis
Robert MacNeill1, Samuel Thomas1, Prachi Anand1
1Labcorp Bioanalytical Services LLC, Princeton, New Jersey08875-2360, United States.
Abstract:
The reliably accurate and precise quantification of biomarkers is a priceless objective in the drug development and diagnostic arenas. To employ a technique that brings such reliability and furthermore involves a simpler, faster, and inexpensive regime would only underline the potential importance of the concept and technique. To the existing established approaches for biomarker quantification in bioanalytical LC-MS, surrogate matrix (SUR-M) and surrogate analyte (SUR-A), in this Letter we present an approach that fulfills the aforementioned advantages. The concept builds on the historic method of standard addition (SA), in which one source of biological matrix is spiked with analyte to form a calibration curve. With the SA curve back-calculated, the heart of this procedure is the subsequent adjustment of the intercept to zero, the origin, and using only the slope of the curve for interpolation giving calculated sample concentrations. In SA, the concentration axis intercept indicates the endogenous analyte concentration, and our zeroing of this is equivalent to removing the endogenous level. This key shift of the calculated line to the origin unveils our novel origin-adjusted (OA) approach. It enables use akin to a regular xenobiotic method, with no need to ultimately account for the endogenous analyte level in the control matrix used for calibrants. We present a comparison of OA against the control approach of SUR-M in a representative application for kynurenine and tryptophan in human plasma by LC-MS. A numerical performance analysis performed is demonstrative of equivalence between the two approaches for both analytes.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
08:03A Tandem Liquid Chromatography–Mass Spectrometry-based Approach for Metabolite Analysis of Staphylococcus aureus
Published on: March 28, 2017
Related Concept Videos
Mass Spectrometry: Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Mass Spectrometry: Isotope Effect
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...