Related Experiment Video
Updated: Aug 15, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Comparison of fiberoptic bronchoscopic intubation using silicone and polyvinyl chloride double-lumen tubes
Seyoon Kang1, Yun Jeong Chae1, Dae Hee Kim2
1Department of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Korea.
Background:
Direct insertion of a double-lumen tube (DLT) using a flexible fiberoptic bronchoscope (FOB) is an option for DLT intubation. The difficult process of fiberoptic intubation is that the different properties of polyvinyl chloride and silicone DLTs may affect railroading differently. Therefore, we aimed to compare intubation using polyvinyl chloride and silicone DLTs over an FOB.
Methods:
Patients aged 19-75 years who required one-lung ventilation under general anesthesia were enrolled in this study. After induction of anesthesia, the anesthesiologist intubated the DLT using FOB. The primary outcome was the difficulty of railroading over the flexible FOB scaled into five grades (I, II-1, II-2, III, and IV). Additionally, the intubation time and mucosal damage were recorded.
Results:
A total of 46 patients participated in this study, 23 each in the silicone and polyvinyl groups. The difficulty of railroading over the FOB was significantly different between the two groups (P < 0.001). In the silicone group, the grades of difficulty in railroading were limited to I and II-1; 20 patients (87%) presented no difficulty in advancing the tube. In contrast, in the polyvinyl group, 13 patients (57%) had scores of II-2 and III. Both the intubation time and mucosal damage were significantly better in the silicone group than in the polyvinyl group.
Conclusions:
Intubation using a silicone DLT over an FOB was easier and faster than that with a polyvinyl chloride DLT with lesser trauma around the glottis.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...