Related Experiment Video
Updated: Aug 1, 2026

A Microfluidic Chip for the Versatile Chemical Analysis of Single Cells
Published on: October 15, 2013
Design and simulation of a novel integrated microfluidic chip for cell isolation and culture
Seyed Ali Tabatabaei1, Javane Javaherchian2
1Department of Mechanical Engineering, University of Tehran, Tehran, Iran.
Abstract:
The lab on a chip is utilized as a background and a substrate for creating a proper flow for cellular processes in medicine. In this study, the concepts of cell isolation and cell transfer methods have been discussed. After that, the device of separation and transfer systems has been designed, simulated, and verified by placing the frequency of particle separation and droplet formation, which is tried to introduce a new device that can be used in cellular studies. The optimal operation conditions for the problem have also been investigated. High separation efficiency (99%) could be achieved when the velocity of the sample inlet in the microchannel separator is 180 μm/s. Also, a microfluidic device for droplet generation has been designed to transfer the isolated cells to the culture medium. For this purpose, the frequency of droplet production must be synchronized with particle ejection frequency and equals 9.09 Hz.