Related Experiment Video
Updated: Aug 15, 2025

Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Current distribution monitoring enables quench and damage detection in superconducting fusion magnets
Reed Teyber1, Jeremy Weiss2,3, Maxim Marchevsky4
1Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA. rteyber@lbl.gov.
Abstract:
Fusion magnets made from high temperature superconducting ReBCO CORC® cables are typically protected with quench detection systems that use voltage or temperature measurements to trigger current extraction processes. Although small coils with low inductances have been demonstrated, magnet protection remains a challenge and magnets are typically operated with little knowledge of the intrinsic performance parameters. We propose a protection framework based on current distribution monitoring in fusion cables with limited inter-cable current sharing. By employing inverse Biot-Savart techniques to distributed Hall probe arrays around CORC® Cable-In-Conduit-Conductor (CICC) terminations, individual cable currents are recreated and used to extract the parameters of a predictive model. These parameters are shown to be of value for detecting conductor damage and defining safe magnet operating limits. The trained model is then used to predict cable current distributions in real-time, and departures between predictions and inverse Biot-Savart recreated current distributions are used to generate quench triggers. The methodology shows promise for quality control, operational planning and real-time quench detection in bundled CORC® cables for compact fusion reactors.
Related Concept Videos
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Magnetic Field Of A Current Loop
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Force On A Current Loop In A Magnetic Field
Magnetic Force On Current-Carrying Wires: Example
Continuous Charge Distributions
The electric charge can also be subjected to an analogical...