Related Experiment Video
Updated: Aug 15, 2025

Retinal Vascular Reactivity as Assessed by Optical Coherence Tomography Angiography
Published on: March 26, 2020
Haemodynamic effects of a 10-min treatment with a high inspired oxygen concentration in the emergency department: a
Renate Stolmeijer1, Ellen van Ieperen2, Heleen Lameijer2
1Department of Emergency Medicine, University Medical Centre Groningen, Groningen, The Netherlands t.m.stolmeijer@umcg.nl.
Abstract:
Previous studies show that prolonged exposure to a high inspired oxygen concentration (FiO2) is associated with unfavourable haemodynamic effects. Until now, it is unknown if similar effects also occur after oxygen therapy of limited duration in the emergency department (ED).
Objectives:
To investigate the haemodynamic effects of a high FiO2 administered for a limited duration of time in patients who receive preoxygenation for procedural sedation and analgesia (PSA) in the ED.
Design, Settings And Participants:
In a prospective cohort study, cardiac output (CO), stroke volume (SV) and systemic vascular resistance (SVR) were measured using the Clearsight non-invasive CO monitoring system in patients who received preoxygenation for PSA in the ED. Measurements were performed at baseline, after 5 min of preoxygenation via a non-rebreathing mask at 15 /L min and after 5 min of flush rate oxygen administration.
Outcomes Measures:
The primary outcome was defined as the change in CO (L/min) from baseline after subsequent preoxygenation with 15 L/min and flush rate.
Results:
Sixty patients were included. Mean CO at baseline was 6.5 (6.0-6.9) L/min and decreased to 6.3 (5.8-6.8) L/min after 5 min of oxygen administration at a rate of 15 L/min, and to 6.2 (5.7-6.70) L/min after another 5 min at flush rate (p=0.037). Mean SV remained relatively constant during this period, whereas mean SVR increased markedly (from 781 (649-1067), to 1244 (936-1695) to 1337 (988-1738) dyn/s/cm-5, p<0.001. Sixteen (27%) patients experienced a>10% decrease in CO.
Conclusion:
Exposure of patients to a high FiO2 for 5-10 min results in a significant drop in CO in one out of four patients. Therefore, even in the ED and in prehospital care, where oxygen is administered for a limited amount of time, FiO2 should be titrated based on deficit whenever this is feasible and high flow oxygen should not be given as a routine treatment.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Oxygen Transport in the Blood
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...