Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Freehand Pre-drilling Technique for Lateral Mass Screw Fixation Is More Efficient and Reliable Versus Sequential
Daren J McCalla1, Takashi Hirase2, Jacob C Hoffmann3
1Spine Surgery, Houston Scoliosis and Spine Institute, Houston, USA.
Abstract:
Background Since posterior cervical fixation with lateral mass screws was introduced in 1979, multiple techniques have been described in the literature. However, no study to date has determined whether pre-drilling all lateral masses prior to screw insertion has a benefit over the traditional sequential drilling and screw insertion on the alignment of the screw-rod construct. This study sought to determine the efficacy and efficiency in achieving alignment with a novel pre-drilling technique compared to the traditional sequential drilling technique. The authors hypothesized that the novel pre-drilling technique could be applied more quickly and precisely than the traditional sequential drilling technique. Methods Eight cervical spine sawbones models were utilized to place 64 lateral mass screws by two surgeons. The pre-drilling technique was utilized to place 32 screws in four models, and the sequential drilling technique was utilized to place the 32 screws in the remaining four models. In the traditional sequential drilling technique, each lateral mass underwent screw tract preparation and insertion before proceeding to the subsequent vertebra. In the pre-drilling technique, all lateral masses were marked and drilled sequentially before screw placement. CT imaging with 3D reconstructions was generated for all models. Variability in screw placement and time taken to fully instrument the models were compared. Results The mean time to completion of the pre-drilling technique was 337 ± 22 seconds compared to 490 ± 22 seconds with the traditional technique (p<0.01). There was a significantly higher variability in the coronal plane within the traditional group between C5 and C6 compared to other adjacent vertebrae (p<0.05). There was no significant difference in the start point variability and the overall tightness of line fit between the techniques. Conclusions Our study suggests that a novel pre-drilling technique for lateral mass screw insertion may be more efficient and reliable than the traditional sequential drilling technique. In addition, this technique may reduce the need for rod contouring or additional implants to optimize the alignment of cervical instrumentation. However, further clinical studies are necessary to validate the potential clinical and radiologic benefits of this described technique.
More Related Videos
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.