Related Experiment Video
Updated: Aug 15, 2025

Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Evaluation of continuous aspiration of subglottic secretions in prevention of microaspiration during general
Boris Mraovic1, Brian Hipszer, Channy Loeum
1Boris Mraovic, Department of Anesthesiology and Perioperative Medicine, School of Medicine, University of Missouri-Columbia, One Hospital Dr., DC005.00 Columbia, MO 65212, USA, mraovicb@health.missouri.edu.
Aim:
To assess the difference between endotracheal tubes (ETT) with continuous suction of subglottic secretions (CASS) and standard ETT in preventing secretions movement from the pharynx into the trachea, past the inflated cuff during general anesthesia.
Methods:
This randomized, controlled trial enrolled 50 patients who underwent general anesthesia for elective abdominal surgery lasting longer than two hours. They received either ETT with CASS: Teleflex ISIS HVT (GISIS, n=17) or Mallinckrodt TaperGuard Evac (GEvac, n=17), or ETT without suction: Mallinckrodt Intermediate Hi-Lo (GStand, n=16). Methylene blue dye solution (10 mL) was delivered into the hypopharynx every 60 minutes. Subglottic secretions were continuously suctioned. Fiberoptic bronchoscopy was performed every 20 minutes and during tracheal extubation to evaluate the dye location.
Results:
The groups did not differ in age, sex, body mass index, race, American Society of Anesthesiologists status, and surgery type. Dye migrated past the inflated cuff into the distal trachea in no patient with ETT with CASS and in 13% of patients with standard ETT. On tracheal extubation, dye migrated into the distal trachea more often in the GStand group (56%), compared with the GEvac (13%) and GISIS group (29%) (P=0.045). The GISIS group had 26±19 mL of secretions suctioned from above the inflated cuff, while the GEvac group had 13±10 mL (P=0.05).
Conclusion:
Compared with standard ETT, ETT with CASS efficiently removed secretions during general anesthesia, prevented secretions from migrating past the inflated cuff, and significantly reduced the amount of secretions that reached the distal airways on tracheal extubation.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
07:22Minimally Invasive Murine Laryngoscopy for Close-Up Imaging of Laryngeal Motion During Breathing and Swallowing
Published on: December 1, 2023
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...