Related Experiment Video
Updated: Aug 15, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Characterization and identification of atrial fibrillation drivers in patients with nonparoxysmal atrial fibrillation
Chin-Yu Lin1,2, Chia-Hsin Chiang1,3,4, Abigail Louise D Te1,5
1Department of Medicine, Division of Cardiology, Heart Rhythm Center, Taipei Veterans General Hospital, Taipei, Taiwan.
Instruction:
We hypothesized that real-time simultaneous amplitude frequency electrogram transform (SAFE-T) during sinus rhythm (SR) is able to identify and characterize the drivers of atrial fibrillation (AF) in nonparoxysmal (NP) AF.
Methods:
Twenty-one NPAF patients (85.71% males, mean age 52 years old) underwent substrate mapping during SR (SAFE-T and voltage) and during AF (complex fractionated atrial electrograms [CFAE] and similarity index [SI]). After pulmonary veins isolation, extensive substrate ablation was performed with the endpoint of procedural termination or elimination of all SI sites (>63% similarities). Sites with procedural termination and non-termination sites were tagged for postablation SR analysis using SAFE-T.
Results:
In 74 CFAE sites identified (average of 3 ± 2 sites per person), 28 (37.84%) were identified as termination sites demonstrating a high SI compared with the non-termination sites (80.11 ± 9.57% vs. 45.96 ± 13.38%, p < .001) during AF. During SR, these termination sites have high SAFE-T values and harbor a highly resonant, localized, repetitive high frequency components superimposed in the low frequency components compared with non-termination sites (5.70 ± 3.04 vs. 1.49 ± 1.66 Hz·mV, p < .001). In the multivariate analysis, the termination sites have higher SAFE-T and SI value (p < .001).
Conclusion:
AF procedural termination sites harbored signal characteristics of repetitive, high frequency component of individualized electrogram during SR, which can be masked by the low frequency fractionated electrogram and are difficult to see from the bipolar electrogram. Thus, SAFE-T mapping is feasible in identifying and characterizing sites of AF drivers.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias V: Evaluating Dysrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias IV: Characteristics of Bradyarrhythmias

