Related Experiment Video
Updated: Aug 15, 2025

Author Spotlight: Advancing Cardiac Procedure Testing Prior to Embarking on Large Animal Studies
Published on: August 25, 2023
Externally mounted versus internally mounted leaflet aortic bovine pericardial bioprosthesis: meta-analysis
Yujiro Yokoyama1, Yosuke Sakurai2, Toshiki Kuno3
1Department of Surgery, St. Luke's University Health Network, Bethlehem, PA, USA.
Background:
Recent studies reported higher-than-expected rates of early structural valve degeneration (SVD) and/or reoperation of externally mounted leaflet aortic bioprosthesis compared with others. This meta-analysis aims to compare the outcomes of bioprostheses with externally versus internally mounted leaflet design in patients who underwent surgical aortic valve replacement (SAVR).
Methods:
MEDLINE and EMBASE were searched through November 2021 to identify comparative studies investigating outcomes following SAVR with either externally or internally mounted leaflet aortic bioprosthesis. Outcomes of interest were reoperation for SVD or any cause and all-cause mortality.
Results:
Our analysis included 15 observational studies that enrolled a total of 23,539 patients who underwent SAVR using externally mounted (n = 9338; 39.7%) or internally mounted leaflet (n = 14,201; 60.3%) bioprostheses. Externally mounted valves consisted of the Trifecta (Abbott, St Paul, MN) (n = 6146) and the Mitroflow (LivaNova, London, UK) (n = 3192), and all internally mounted valves were the Perimount (Edwards Lifesciences, Irvine, CA). Externally mounted valves compared with the Perimount were associated with higher reoperation rates for SVD [hazard ratio (HR) 3.55, 95% confidence interval (CI) 2.67-4.72; P < 0.001] and any cause (HR 9.36, 95% CI 3.70-23.67; P < 0.001). Furthermore, externally mounted valves demonstrated higher all-cause mortalities (HR 1.33, 95% CI 1.13-1.56; P < 0.001).
Conclusions:
The present study summarizing updated evidence revealed higher reoperation rates and all-cause mortalities in patients with externally mounted leaflet aortic bioprostheses compared with those with internally mounted design. Choosing the right SAVR valve type is critical part of lifetime management of aortic valve disease.
More Related Videos
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017