Related Experiment Video
Updated: Aug 15, 2025

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Distal Metaphyseal Ulnar Shortening Osteotomy Fixation: A Biomechanical Analysis
Christopher S Frey1, Joanne Y Zhou1, Kalpit N Shah2
1Department of Orthopaedic Surgery, Stanford University, Redwood City, CA.
Purpose:
Ulnar shortening osteotomy can be used to treat ulnar impaction syndrome and other causes of ulnar wrist pain. Distal metaphyseal ulnar shortening osteotomy (DMUSO) is one technique that has been proposed to reduce the complications seen with a diaphyseal USO or a wafer resection. However, to our knowledge, the optimal fixation construct for DMUSO has not been studied. We sought to characterize the biomechanical stiffness and rotational stability of different DMUSO constructs.
Methods:
A DMUSO was performed on 40 human cadaveric ulnas using 4 different fixation constructs (10 specimens per group): one 3.0 mm antegrade screw; two 2.2 mm antegrade screws; one 3.0 mm retrograde screw; and two 2.2 mm retrograde screws. Biaxial testing using axial load and cyclical axial torque was performed until failure, defined as 10° of rotation or 2 mm displacement. Specimens were assessed for stiffness at failure. Bone density was assessed using the second metacarpal cortical percentage.
Results:
Bone density was similar between all 4 testing groups. Of the 4 groups, the 2 antegrade screw group exhibited the highest rotational stiffness of 232 ± 102 Nm/deg. In paired analysis, this was significantly greater than 1 retrograde screw constructs. In multivariable analysis, 2-screw constructs were significantly stiffer than 1 screw and antegrade constructs were significantly stiffer than retrograde. Maximum failure torque did not differ with orientation, but 2 screws failed at significantly higher torques.
Conclusion:
Using 2 screws for DMUSO fixation constructs may provide higher stiffness and maximum failure torque, and antegrade screw constructs may provide more stiffness than retrograde constructs.
Clinical Relevance:
Antegrade screw fixation using 2 screws may provide the strongest construct for DMUSO. Antegrade fixation may be preferred because it avoids violating the distal radioulnar joint capsule and articular surface of the ulna.