Related Experiment Video
Updated: Aug 15, 2025

Machine Learning Algorithms for Early Detection of Bone Metastases in an Experimental Rat Model
Published on: August 16, 2020
CT-Based Radiomics Can Predict the Efficacy of Anlotinib in Advanced Non-Small-Cell Lung Cancer
Jingyu Chen1, Chuhuai Wang1,2, Weinuo Qu3
1Department of Oncology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, Hubei, China.
Abstract:
Anlotinib is a small-molecule RTK inhibitor that has achieved certain results in further-line treatment, but many patients do not respond to this drug and lack effective methods for identification. Although radiomics has been widely used in lung cancer, very few studies have been conducted in the field of antiangiogenic drugs. This study aims to develop a new model to predict the efficacy of patients receiving anlotinib by combining pretreatment computed tomography (CT) radiomic characters with clinical characters, in order to assist precision medicine of pulmonary cancer. 254 patients from seven institutions were involved in the study. Lesions were selected according to the RECIST 1.1 criteria, and the corresponding radiomic features were obtained. We constructed prediction models based on clinical, NCE-CT, and CE-CT radiomic features, respectively, and evaluated the prediction performance of the models for training sets, internal validation sets, and external validation sets. In the RAD score only model, the area under curve(AUC) of the NCE-CT cohort was 0.740 (95% CI: 0.622, 0.857) for the training set, 0.711 (95% CI: 0.480, 0.942) for the internal validation set, and 0.633(95% CI: 0.479, 0.787) for the external validation set, while that of the CE-CT cohort was 0.815 (95% CI: 0.705, 0.926) for the training set, 0.771 (95% CI: 0.539, 1.000) for the internal validation set, and 0.701 (95% CI: 0.489, 0.913) for the external validation set. In the RAD score-combined model, the AUC of the NCE-CT cohort was 0.796 (95% CI: 0.691, 0.901) for the training set, 0.579 (95% CI: 0.309, 0.848) for the internal validation set, and 0.590 (95% CI: 0.427, 0.753) for the external validation set, while that of the CE-CT cohort was 0.902 (95% CI: 0.828, 0.977) for the training set, 0.865 (95% CI: 0.696, 1.000) for the internal validation set, and 0.837 (95% CI: 0.682, 0.992) for the external validation set. In conclusion, radiomics has accurate predictions for the efficacy of anlotinib. CE-CT-based radiomic models have the best predictive potential in predicting the efficacy of anlotinib, and model predictions become better when they are combined with clinical characteristics.
Insights
Radiomics accurately predicts anlotinib efficacy in pulmonary cancer patients. Combining contrast-enhanced CT (CE-CT) radiomic features with clinical data offers the best predictive model for personalized treatment.
Area of Science:
- Oncology
- Radiology
- Precision Medicine
Background:
- Anlotinib, a tyrosine kinase inhibitor, shows efficacy in advanced cancers but patient response varies.
- Predictive biomarkers for anlotinib response are lacking, hindering personalized treatment strategies.
- Radiomics, analyzing imaging features, has potential but is underexplored for antiangiogenic drug efficacy prediction.
Purpose of the Study:
- To develop and validate a radiomic model for predicting anlotinib treatment efficacy in pulmonary cancer patients.
- To investigate the added value of combining computed tomography (CT) radiomic features with clinical data for improved prediction.
- To compare the predictive performance of models based on non-contrast-enhanced CT (NCE-CT) and contrast-enhanced CT (CE-CT) imaging.
Main Methods:
- A multi-institutional study involving 254 pulmonary cancer patients treated with anlotinib.
- Radiomic features were extracted from pre-treatment NCE-CT and CE-CT scans.
- Prediction models were built using radiomic features alone and combined with clinical characteristics, validated internally and externally.
Main Results:
- CE-CT-based radiomic models demonstrated superior predictive performance compared to NCE-CT models.
- The combined model incorporating CE-CT radiomic features and clinical data achieved the highest predictive accuracy (AUC up to 0.902 in training and 0.837 in external validation).
- Radiomics, particularly with CE-CT, shows significant potential in predicting anlotinib response.
Conclusions:
- Radiomics offers a non-invasive and accurate method for predicting anlotinib efficacy in pulmonary cancer.
- Contrast-enhanced CT (CE-CT) radiomic features combined with clinical data provide the most robust predictive model.
- This approach can aid in patient selection for anlotinib therapy, advancing precision medicine in oncology.
More Related Videos
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018