Related Experiment Video
Updated: Aug 15, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Development and validation of a deep learning model to diagnose COVID-19 using time-series heart rate values before
Heewon Chung1, Hoon Ko1, Hooseok Lee1
1Department of Biomedical Engineering, College of Electronics and Information, Kyung Hee University, Yongin-si, South Korea.
Abstract:
One of the effective ways to minimize the spread of COVID-19 infection is to diagnose it as early as possible before the onset of symptoms. In addition, if the infection can be simply diagnosed using a smartwatch, the effectiveness of preventing the spread will be greatly increased. In this study, we aimed to develop a deep learning model to diagnose COVID-19 before the onset of symptoms using heart rate (HR) data obtained from a smartwatch. In the deep learning model for the diagnosis, we proposed a transformer model that learns HR variability patterns in presymptom by tracking relationships in sequential HR data. In the cross-validation (CV) results from the COVID-19 unvaccinated patients, our proposed deep learning model exhibited high accuracy metrics: sensitivity of 84.38%, specificity of 85.25%, accuracy of 84.85%, balanced accuracy of 84.81%, and area under the receiver operating characteristics (AUROC) of 0.8778. Furthermore, we validated our model using external multiple datasets including healthy subjects, COVID-19 patients, as well as vaccinated patients. In the external healthy subject group, our model also achieved high specificity of 77.80%. In the external COVID-19 unvaccinated patient group, our model also provided similar accuracy metrics to those from the CV: balanced accuracy of 87.23% and AUROC of 0.8897. In the COVID-19 vaccinated patients, the balanced accuracy and AUROC dropped by 66.67% and 0.8072, respectively. The first finding in this study is that our proposed deep learning model can simply and accurately diagnose COVID-19 patients using HRs obtained from a smartwatch before the onset of symptoms. The second finding is that the model trained from unvaccinated patients may provide less accurate diagnosis performance compared with the vaccinated patients. The last finding is that the model trained in a certain period of time may provide degraded diagnosis performances as the virus continues to mutate.
More Related Videos
Related Concept Videos
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...