Related Experiment Video
Updated: Aug 15, 2025

Milk Collection in the Rat Using Capillary Tubes and Estimation of Milk Fat Content by Creamatocrit
Published on: December 16, 2015
Rapid quantification of goat milk adulteration with cow milk using Raman spectroscopy and chemometrics
Wangfang Li1, Wei Huang1, Desheng Fan1
1MOE Key Laboratory of Laser Life Science & Laboratory of Photonic Chinese Medicine, College of Biophotonics, South China Normal University, Guangzhou 510631, China. yaoyongmeng@aliyun.com.
Abstract:
As goat milk has a higher economic value compared to cow milk, the phenomenon of adulterating goat milk with cow milk appears in the market. In this study, the potential of Raman spectroscopy along with chemometrics was investigated for the authentication and quantitation of liquid goat milk adulterated with cow milk. First, the results of principal component analysis (PCA) showed that there were differences between the Raman spectra of cow and goat milk, which made quantitative experiments possible. For quantification, three different brands of cow milk and goat milk were selected randomly and adulterated goat milk with cow milk at the proportion of 5-95%. 342 samples were used for the construction of the partial least squares regression (PLSR) model with 80% for the calibration set and 20% for the prediction set. The PLSR model showed excellent performance in quantifying the level of adulteration, for the prediction set, with a coefficient of determination (R2) of 0.9781, root mean square error (RMSE) of 3.82%, and a ratio of prediction to deviation (RPD) of 6.8. The results demonstrated the potential of Raman spectroscopy as a rapid, low cost and non-destructive analytical tool for detecting adulteration in goat milk.
More Related Videos
09:26Species Determination and Quantitation in Mixtures Using MRM Mass Spectrometry of Peptides Applied to Meat Authentication
Published on: September 20, 2016
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...