Abstract:
We present experimental determination of the energies associated with the gradual desorption of Ar atoms from the aromatic molecular surface. Non-covalently bound 2,2'-pyridylbenzimidazole-Ar1-3 complexes were produced in the gas phase and characterized using resonant two-photon ionization (R2PI) spectroscopy. The single Ar desorption from the PBI-Ar, PBI-Ar2 and PBI-Ar3 complexes were measured as 581 ± 18, 656 ± 30 and 537 ± 31 cm-1, respectively. The energies were bracketed between the last observed band in the respective R2PI spectra and the disappeared intramolecular modes of PBI. The Ar dissociation energies in the S1 state were measured as 581 ± 18, 1237 ± 48 and 1774 ± 79 cm-1, respectively, for n = 1, 2 and 3. The calculated dissociation energies of the respective complexes, obtained using three computational methods, show excellent agreement with the experimental data. The ground state dissociation energies were estimated by subtracting the Δν shift of the origin band, and the respective values are 541 ± 18, 1160 ± 48 and 1634 ± 79 cm-1. Overall, the calculated values resulted in scaling factors ranging from 0.956 to 1.017, which depict the predictive power of the methods to determine dispersion energies. The current investigation describes a unique methodology to accurately determine the dissociation and desorption energies of Ar atoms from the surfaces of bio-relevant aromatic molecules.
More Related Videos
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Fluorescence Spectroscopy
Atomic Absorption Spectroscopy: Atomization Methods