Study on smoke blocking and thermal radiation attenuation by water curtain in tunnel fire
Yinuo Chen1,2, Jinzhang Jia3,4, Guangbo Che5,6,7
1School of Safety Science and Engineering, Liaoning Technical University, Fuxin, 123000, Liaoning, China.
Abstract:
A 1:10 scale model tunnel with a length, height and width of 9 m, 0.6 m and 0.8 m, respectively, was set up in this paper. A water curtain system was installed in the model to investigate the effect of water curtain systems on smoke flow and heat propagation. A reduced-scale experimental and theoretical study was carried out by varying the heat release rate of the fire source, the water curtain pressure, and the number of water curtain rows. A series of tests were carried out for various setups to quantify each mechanism of interaction between the water mist and hot smoke, to propose a method for qualitatively analysing water curtain systems blocking the propagation of heat radiation and the flow of smoke from combustion, and to propose a method for predicting heat fluxes. The study found that the pressure of the water curtain, the number of rows, and the heat release rate of the fire source all had an effect on the smoke blocking effect of the water curtain system. This effect decreased as the heat release rate of the fire source increased and increased significantly with the pressure of the water curtain and the number of rows. The smoke blocking effect was quantified using conservation of momentum by establishing a dimensionless parameter R to represent the ratio of water curtain momentum to smoke momentum, as well as the ratio of heat flux before and after the water curtain to represent the smoke blocking capacity [Formula: see text] of the water curtain. The smoke blockage rate [Formula: see text] ranges between 40 and 75%, and the smoke blockage rate increases as the momentum R increases. Finally, in tunnel fires, a predictive model for the attenuation of heat radiation by water curtains has been developed, providing theoretical support for the quantitative study of the smoke and thermal blockage effects of water curtains, which is beneficial to the protection of human life in confined spaces.
Related Concept Videos
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....
Masonry Curtain Walls
Radiation: Applications
The average...
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...