Related Experiment Video
Updated: Aug 15, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Comparative evaluation of flexural strength of denture base resin materials processed using compression molding
Rutika C Patankar1, Vijaysinh More1, Rajashree Jadhav1
1Department of Prosthodontics, Crown and Bridge, and Implantology, Bharati Vidyapeeth Dental College and Hospital (Deemed to be University), Pune, Maharashtra, India.
Background:
Denture bases undergo repeated flexing during mastication leading to fatigue failure, demanding a high fatigue strength property. Flexural (transverse) strength is required high to prevent catastrophic failure under load for success. Denture base resins are fabricated by three different types of manufacturing: Compression molding, injection molding and computer-aided design (CAD/CAM) milling technique. The study was conducted to identify the denture with the highest flexural strength (Fs) from these methods.
Materials And Methods:
In this in vitro study. Three groups of 15 PMMA acrylic denture base resins (total 45) were processed into rectangular plates of size 65mm × 10mm × 3mm. The three groups differed in the method of processing as compression molded, injection molded, and prepolymerized CAD/CAM milled resins. A 3-point bend test was used to measure the Fs. One-way analysis of variance (ANOVA) with the Post hoc Tukey method was used for statistical analysis. Data was statistically significant with Post hoc Tukey method significance at P < 0.05.
Results:
The mean Fs of CAD/CAM, injection molding, and compression molding manufacturing techniques are 97.46, 84.42, and 71.72 respectively and standard deviation obtained are 9.93, 10.42, and 11.58, respectively. Statistical analysis suggested the CAD/CAM technique as the best method for the fabrication of dentures because it had the maximum mean Fs and the lowest Fs standard deviation when compared with compression molding and injection molding.
Conclusion:
Denture bases fabricated through CAD/CAM technique are more sustainable than the compression-molded and injection-molded denture bases.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to...