Related Experiment Video
Updated: Aug 15, 2025

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Evaluation of Chinese populational exposure to environmental electromagnetic field based on stochastic dosimetry and
Yuwei Jiang1, Hongkai Wang2, Xiaobang Sun2,3
1China Academy of Information and Communications Technology, No. 52, Huayuan Bei Road, Beijing, 100191, China.
Abstract:
This study aimed to estimate the distribution of the whole-body averaged specific absorption rate (WBSAR) using several measurable physique parameters for Chinese adult population exposed to environmental electromagnetic fields (EMFs) of current wireless communication frequencies, and to discuss the effects of these physique parameters in the frequency-dependent dosimetric results. The physique distribution of Chinese adults was obtained from the National Physical Fitness and Health Database comprising 81,490 adult samples. The number of physique parameters used to construct the surrogate model was reduced to three via mutual information analysis. A stochastic method with 40 deterministic simulations was used to generate frequency-dependent and gender-specific surrogate models for WBSAR via polynomial chaos expansion. In the simulations, we constructed anatomically correct models conforming to the targeted physique parameters via deformable human modelling technique, which was based on deep learning from the image database including 767 Chinese adults. Thereafter, we analysed the sensitivity of the physique parameters to WBSAR by covariance-based Sobol decomposition. The results indicated that the generated models were consistent with the targeted physique parameters. The estimated dosimetric results were validated using finite-difference time-domain simulations (the error was < 6% across all the investigated frequencies for WBSAR). The novelty of the study included that it demonstrated the feasibility of estimating the individual WBSAR using a limited number of physique parameters with the aid of surrogate modelling. In addition, the population-based distribution of the WBSAR in Chinese adults was firstly presented in the manuscript. The results also indicated that the different combinations of physique parameter, dependent on genders and frequencies, significantly influenced the WBSAR, although the general conservativeness of the guidelines of the International Commission on Non-Ionizing Radiation and Protection can be confirmed in the surveyed population.
Related Concept Videos
Mechanistic Models: Compartment Models in Individual and Population Analysis
Biological Effects of Radiation
Analysis of Population Pharmacokinetic Data
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Parametric Survival Analysis: Weibull and Exponential Methods
Weibull Distribution
The Weibull distribution is a flexible model used in parametric survival analysis. It can handle both increasing and decreasing hazard rates, depending on its shape parameter...