Related Experiment Video
Updated: Aug 15, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Clinical usefulness of end-tidal CO2 measured using a portable capnometer in patients with respiratory disease
Manabu Suzuki1, Shota Fujimoto1, Keita Sakamoto1
1Department of Respiratory Medicine, National Center for Global Health and Medicine, Tokyo, Japan.
Introduction:
This study aimed to evaluate the correlation and agreement between end-tidal CO2 (EtCO2 ) measured with the novel portable capnometer (CapnoEye®) and partial pressure of arterial carbon dioxide (PaCO2 ) levels in patients with respiratory diseases and to compare the efficacy of EtCO2 and PvCO2 in predicting PaCO2 levels.
Methods:
We analyzed the correlation and the agreement between EtCO2 and PaCO2 and between PvCO2 and PaCO2 using Pearson's moment correlation coefficient in patients with type 1 and type 2 respiratory failure and both groups overall.
Results:
A total of 100 samples were included that comprised 67 men (67%). The mean age of the subjects was 77 ± 13 years. Chronic obstructive pulmonary disease (COPD) (43%) was the most common disease. There was a high correlation between EtCO2 and PaCO2 (r = 0.88; p < 0.0001). Sixty-six PvCO2 samples were obtained, and there was a high correlation between PvCO2 and PaCO2 (r = 0.81; p < 0.0001). Regarding type 2 respiratory failure, there was a high correlation between EtCO2 and PaCO2 (r = 0.81). The Bland-Altman analysis between PaCO2 and EtCO2 revealed a bias of 5.7 mmHg, with limits of agreement ranging from -5.1 mmHg to 16.5 mmHg. In contrast, the analysis between PaCO2 and PvCO2 revealed a bias of -6.8 mmHg, and the limits of agreement ranged from -22.13 mmHg to 8.53 mmHg.
Conclusion:
EtCO2 measured by CapnoEye® was significantly correlated to PaCO2 levels in patients with respiratory diseases. Moreover, CapnoEye® may be more useful for predicting hypercapnia conditions in which respiratory diseases are compared with measure PvCO2 .
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Acute Respiratory Failure-III
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...