Ventricular assist device support for failing Glenn circulation: Impact of concomitant Fontan completion in select
Jiyong Moon1, Hari Tunuguntla2, Sebastian Tume3
1Congenital Heart Surgery, Michael E. DeBakey Department of Surgery, Texas Children's Hospital, Baylor College of Medicine, Houston, Texas; Section of Pediatric Cardiovascular Surgery, Department of Cardiac Surgery, C.S. Mott Children's Hospital, University of Michigan, Ann Arbor, Michigan.
Background:
Ventricular assist device (VAD) support for failing Glenn circulation represents a unique challenge.
Methods:
We conducted a retrospective review of clinical outcomes in patients with VAD support for failing Glenn circulation between 2010 and 2020 at a tertiary pediatric institution.
Results:
Ten patients were included: INTERMACS profiles were 1 in 3 patients and 2 in 7 patients. The median age, weight, and body surface area were 3.2 years, 13.0 kg, and 0.5 m2, respectively. Seven patients (70%) were implanted with continuous-flow devices and 3 with para-corporeal devices. Nine patients (90%) received heart transplant, with a median support duration of 77 days. Four (67%) out of 6 patients supported with discharge-capable devices were managed as outpatients. Post-transplant survival was 100%, with a median (range) follow up duration of 3.5 (1.8-11.9) years. There were 3 neurologic complications in 3 patients (0.9 events per patient-year); 2 intraoperative events (fatal hypoxia and symptomatic embolic stroke) and 1 postoperative (asymptomatic subarachnoid hemorrhage). Pump thrombosis occurred in one patient (0.3 events per patient-year), requiring pump exchange at day 65. Five patients (50%) received concomitant Fontan completion (fenestrated in 1). The Fontan-upgraded patients (vs Glenn) tended to be larger (median (range): 15.9 (12.6-22.9) vs 9.1 (7.7-22.8) kg), older (4.7 (3.1-6.5) vs 1.1 (0.9-10.1) years) and had a higher PaO2/FiO2 ratio (192 (52-336) vs 76 (59-78) mm Hg) on postoperative day 1.
Conclusion:
Our experience suggests the feasibility of durable VAD support for failing Glenn circulation. Concomitant Fontan completion may be considered in select patients to improve oxygen delivery.