Related Experiment Video
Updated: Aug 15, 2025

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Correcting Diagnostic Test Sensitivity and Specificity for Patient Misclassifications Resulting from Use of an
1Clinical Development, GE HealthCare, Marlborough, MA 01752, USA.
Abstract:
Investigational diagnostic tests are validated by using a reference standard (RS). If the RS is imperfect (i.e., it has sensitivity [Se] and/or specificity [Sp] < 1), incorrect values for the investigational test’s Se and Sp may result because of patient misclassification by the RS. Formulas were derived to correct a test’s Se and Sp that were determined by using an imperfect RS. The following derived formulas correct for misclassification and give the true numbers of disease-positive [nDP] and disease-negative patients [nDN] from the apparent number of disease-positive and disease-negative patients (anDP and anDN), and the Se and Sp of the RS (SeR, SpR): nDP = (anDP × SpR + anDN × SpR − anDN)/JR; nDN = (anDP × SeR + anDN × SeR − anDP)/JR, where JR is Youden’s Index for the RS (JR = SeR + SpR − 1). The following derived formulas give the correct Se and Sp of an investigational test (SeI and SpI): SeI = (anTPI × SpR − nDP × SeR × SpR + nDP × JR + nDN × SpR2 − nDN × SpR − SpR × anTNI + anTNI)/(nDP × JR); SpI = (anTPI − anTPI × SeR + nDP × SeR2 − nDP × SeR − SeR × nDN × SpR + nDN × JR + SeR × anTNI)/(nDN × JR), where anTPI is the apparent number of true-positive test results, and anTNI is the apparent number of true-negative test results. The derived formulas correct for patient misclassification by an imperfect RS and give the correct values of a diagnostic test’s Se and Sp.
More Related Videos
Related Concept Videos
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Receiver Operating Characteristic Plot
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Errors occurring during blood pressure monitoring
Several factors...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...

