Related Experiment Video
Updated: Aug 15, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Estimation of Stiffness of Non-Cohesive Soil in Natural State and Improved by Fiber and/or Cement Addition under
Katarzyna Zabielska-Adamska1, Patryk Dobrzycki1, Mariola Wasil1
1Faculty of Civil Engineering and Environmental Sciences, Bialystok University of Technology, ul. Wiejska 45E, 15-351 Bialystok, Poland.
Abstract:
The aim of this study was to compare the stiffness of gravelly sand under various load conditions-static conditions using the CBR test and cyclic conditions using the resilient modulus test. The tests were conducted on natural soil and soil improved by the addition of polypropylene fibers and/or 1.5% cement. The impacts of the compaction and curing time of the stabilized samples were also determined. The soil was sheared during the Mr tests, even after fiber reinforcement, so the resilient modulus value for the unbound sand could not be obtained. The cement addition improved Mr, and the curing time also had an impact on this parameter. The fiber addition increased the value of the resilient modulus. The CBR value of the compacted gravelly sand was relatively high. It increased after adding 0.1% fibers in the case of the standard compacted samples. The greater fiber addition lowered the CBR value. For the modified compacted samples, each addition of fibers reduced the CBR value reduced the CBR value. The addition of cement influenced the CBR increase, which was also affected by the compaction method and the curing time. The addition of fibers to the stabilized sample improved the CBR value. The relationship Mr=f(CBR) obtained for all data sets was statistically significant but characterized by a large error of estimate.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Elasticity in Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...