Related Experiment Video
Updated: Aug 15, 2025

Drug Repurposing Hypothesis Generation Using the "RE:fine Drugs" System
Published on: December 11, 2016
Predictors of Metformin Failure: Repurposing Electronic Health Record Data to Identify High-Risk Patients
Suzette J Bielinski1, Licy L Yanes Cardozo2,3,4,5, Paul Y Takahashi6
1Division of Epidemiology, Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN 55905, USA.
Context:
Metformin is the first-line drug for treating diabetes but has a high failure rate.
Objective:
To identify demographic and clinical factors available in the electronic health record (EHR) that predict metformin failure.
Methods:
A cohort of patients with at least 1 abnormal diabetes screening test that initiated metformin was identified at 3 sites (Arizona, Mississippi, and Minnesota). We identified 22 047 metformin initiators (48% female, mean age of 57 ± 14 years) including 2141 African Americans, 440 Asians, 962 Other/Multiracial, 1539 Hispanics, and 16 764 non-Hispanic White people. We defined metformin failure as either the lack of a target glycated hemoglobin (HbA1c) (<7%) within 18 months of index or the start of dual therapy. We used tree-based extreme gradient boosting (XGBoost) models to assess overall risk prediction performance and relative contribution of individual factors when using EHR data for risk of metformin failure.
Results:
In this large diverse population, we observed a high rate of metformin failure (43%). The XGBoost model that included baseline HbA1c, age, sex, and race/ethnicity corresponded to high discrimination performance (C-index of 0.731; 95% CI 0.722, 0.740) for risk of metformin failure. Baseline HbA1c corresponded to the largest feature performance with higher levels associated with metformin failure. The addition of other clinical factors improved model performance (0.745; 95% CI 0.737, 0.754, P < .0001).
Conclusion:
Baseline HbA1c was the strongest predictor of metformin failure and additional factors substantially improved performance suggesting that routinely available clinical data could be used to identify patients at high risk of metformin failure who might benefit from closer monitoring and earlier treatment intensification.
Related Concept Videos
Oral Hypoglycemic Agents: Biguanides and Glitazones
Methods of Documentation VII: EMR
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Kaplan-Meier Approach
Errors occurring during blood pressure monitoring
Several factors...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...