Schiff Base Ligand 3-(-(2-Hydroxyphenylimino) Methyl)-4H-Chromen-4-One as Colorimetric Sensor for Detection of Cu2+,
Ali Q Alorabi1, Sami A Zabin1, Mohammad Mahboob Alam1
1Chemistry Department, Faculty of Science, Albaha University, P.O. Box 1988, Albaha 65799, Saudi Arabia.
Abstract:
The ligand 3-(-(2-hydroxyphenylimino) methyl)-4H-chromen-4-one (SL) has been synthesized and examined as a chemosensor for some metal ions in aqueous solutions based on colorimetric analysis. Color changes were monitored using UV-visible spectroscopy. Binding stoichiometry and limit of detection (LOD) were estimated using titration experimentation based on UV-visible absorbance and Job's plot. The synthesized ligand was tested for selectivity in the presence of several cations and was examined for possible utility as a chemosensor in real water samples. The results indicated sensing ability and selectivity for Cu2+, Fe3+, and V5+. Stable complexes were formed between SL and Cu2+, Fe3+, and V5+, and the ligand-to-metal binding stoichiometry was found 2 : 1 in the SL-Cu2+ and SL-Fe3+ complexes, and 1 : 1 in the SL-V5+ complex. The results of LOD and bending constant were (7.03 μM, 1.37 × 104 M-1), (5.16 μM, 2.01 × 104 M-1), and (5.94 μM, 1.82 × 104 M-1) for Cu2+, Fe3+, and V5+, respectively.
More Related Videos
07:07Synthetic Methodology for Asymmetric Ferrocene Derived Bio-conjugate Systems via Solid Phase Resin-based Methodology
Published on: March 12, 2015
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Complexometric Titration: Overview
Complexometric Titration: Ligands
Extraction: Advanced Methods
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
