Related Experiment Video
Updated: Aug 14, 2025

Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
A retrospective multicenter study comparing the punctures to B2 and B3 in endoscopic ultrasound-guided
Masanari Sekine1, Yusuke Hashimoto2, Taro Shibuki2
1Department of Gastroenterology Jichi Medical University, Saitama Medical Center Saitama Japan.
Objectives:
In recent years, endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) has been performed as an important salvage option for failed endoscopic retrograde cholangiopancreatography for biliary drainage. However, technical issues, such as puncture site (bile duct of segment 3 [B3] or bile duct of segment 2 [B2]), dilation method, stent selection, and procedural safety, need to be resolved for the optimization of EUS-HGS. The present study was to compare the safety, difficulty, and technical and functional success between biliary access via B2 and B3 during EUS-HGS.
Methods:
We conducted a retrospective investigation of 161 consecutive EUS-HGS cases across a total of 6 facilities, including those at our hospital. The patients were divided into two groups according to the successful drainage route: the puncture to B2 (P-B2) or the puncture to B3 (P-B3). We compared the technical and functional success rates, technical difficulty, and adverse events between the two groups. We also conducted a subgroup analysis to show the factors related to the procedure time.
Results:
There were 92 cases in the P-B2 group and 69 cases in the P-B3 group. There were no significant differences in the technical success, functional success, or adverse events between the groups; however, the procedure time was significantly shorter in P-B2 cases than in P-B3 cases. The multivariate analysis showed that the puncture site was the only factor related to the procedure time.
Conclusions:
Based on these findings, P-B2 appears useful and safe. P-B2 is as effective as P-B3 and was able to be performed in a shorter period of time. The B2 approach can be considered a useful option for EUS-HGS.