Related Experiment Video
Updated: Aug 14, 2025

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
Tightrope Technique for facilitating complex endovascular aortic repair in patients with severely angulated neck
Michael D Spinosa1, Joshua D Adams1,2
1Virginia Tech Carilion School of Medicine, Roanoke, VA.
Abstract:
An 84-year-old presented with a large, symptomatic juxtarenal abdominal aortic aneurysm. Owing to severe angulation of the infrarenal neck, advancement of the distal bifurcated component caused dramatic lateral movement of the proximal physician-modified endovascular graft (PMEG) fenestrated device. This procedure risked aneurysm sac perforation and possible PMEG device displacement. To avoid this complication, the distal aspect of the PMEG device was tethered in place using endoscopic forceps to provide countertraction, similar to pulling a tightrope. This technique allowed for the uneventful placement of the distal bifurcated component without complication. This technique can overcome device placement challenges within an angulated aorta caused by large aneurysms.