Modeling the Environmental and Financial Impact of Multi-dose vs. Single-dose Iodinated Contrast Media Packaging and
Jennifer S Lindsey1, Katherine Frederick-Dyer1, John Jeffrey Carr1
1Department of Radiology, Vanderbilt University Medical Center, Nashville, TN.
Rationale And Objectives:
Iodinated contrast media (ICM) is used in computed tomography (CT) imaging to better visualize pathophysiology. ICM is commonly sold in "single-dose" bottles that require any unused volume to be discarded. Multi-dose bottles have been developed as an alternative packaging method. The objective of this study was to compare ICM waste, plastic waste, and the associated financial costs for both the single-dose and multi-dose ICM delivery systems.
Methods:
Institutional data was used to estimate the average ICM administered per CT scan, average ICM wasted per CT scan, and the total ICM volume wasted annually. Waste estimates for the multi-dose bottles were generated by applying the average ICM administered per CT scan to the larger, multi-dose bottle volumes. Single-dose bottles, multi-dose bottles and injection syringes were weighed and used to calculate plastic waste generated by both packaging methods. Financial analysis was performed to compare the cost of supplies for single-dose and multi-dose ICM delivery systems.
Results:
We found that 100 mL single-dose ICM bottles waste an average of 19.7 mL per CT scan, representing over 964 L of ICM wasted per year. The multi-dose ICM delivery system was projected to decrease pharmaceutical waste by at least 73% and reduce plastic waste by approximately 93%. We also estimate $494,000 in annual savings using the multi-dose ICM delivery method at our institution.
Conclusion:
Multi-dose ICM packaging can help conserve ICM, an important pharmaceutical that was only recently severely affected supply chain disruptions. The multi-dose delivery system can also reduce plastic waste and generate substantial financial savings to offset capital investment.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
08:25Advanced 3D Liver Models for In vitro Genotoxicity Testing Following Long-Term Nanomaterial Exposure
Published on: June 5, 2020
Related Concept Videos
Compartment Models: Two-Compartment Model
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Compartment Models: Single-Compartment Model
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...