Spatiotemporal patterns of early afterdepolarizations underlying abnormal T-wave morphologies in a tissue model of

Mengya Yuan1, Heqiang Lian1, Pan Li1,2

  • 1Henan Engineering Research Center of Health Big Data and Intelligent Computing, School of Public Health, Institutes of Health Central Plains, Xinxiang Medical University, Xinxiang, Henan, P.R. China.

Plos One
|January 9, 2023
PubMed

Insights

Early afterdepolarizations (EADs) can trigger ventricular arrhythmias (VAs) in long QT syndrome (LQTS). This study models EADs in the Purkinje-ventricular system, linking their spatial dynamics to abnormal T-wave morphologies observed in LQTS.

Area of Science:

  • Computational biology
  • Cardiac electrophysiology
  • Medical physics

Background:

  • Sudden cardiac death (SCD) is primarily caused by ventricular arrhythmias (VAs).
  • Early afterdepolarizations (EADs) are cellular events that can trigger VAs, particularly in long QT syndrome (LQTS).
  • The spatial organization of EADs and their link to T-wave abnormalities in LQTS remain incompletely understood.

Purpose of the Study:

  • To investigate the spatial-temporal dynamics of EADs within a Purkinje-ventricular system (PVS) model.
  • To explore the relationship between EAD spatial patterns and T-wave morphologies characteristic of LQTS.
  • To elucidate the mechanisms by which EADs induce and sustain VAs.

Main Methods:

  • Development of a computational tissue model of the Purkinje-ventricular system (PVS).
  • Quantitative analysis of EAD spatial-temporal dynamics under varying ionic current inhibitions (ICal, IKr) and pacing cycle lengths (CLs).
  • Correlation of simulated EAD patterns with T-wave morphologies, including alternans and specific waveform shapes.

Main Results:

  • Moderate ICaL inhibition promotes AP alternans; significant IKr reduction (>50%) at long CLs favors EADs.
  • Minor ICaL reduction links synchronized EADs to T-wave alternans and specific T-wave morphologies (inverted, biphasic, late-appearing, pointed) at increasing CLs.
  • Localized EADs can initiate slow, unidirectional propagation, causing broad-based T-waves; spatially discordant EADs lead to alternating ECG patterns.

Conclusions:

  • The study provides novel insights into the spatiotemporal organization of EADs in the PVS.
  • Mechanistic links are suggested between complex EAD spatial dynamics and observed T-wave abnormalities in LQTS.
  • Understanding these links may offer new perspectives on the mechanisms underlying VA in cardiac channelopathies.

Related Concept Videos

Cardiac Action Potential01:30

Cardiac Action Potential

Cardiac action potentials are essential for proper heart function, enabling the rhythmic contractions needed for adequate blood circulation. Nodal cells and Purkinje fibers, specialized for electrical conduction, generate these action potentials.
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
2.0K
Electrophysiology of Normal Cardiac Rhythm01:19

Electrophysiology of Normal Cardiac Rhythm

The normal cardiac rhythm is a synchronized electrical activity that facilitates the regular and coordinated contraction of the heart muscle. This process is essential for efficient blood circulation throughout the body. The fundamental elements involved in establishing and maintaining this rhythm include the unique electrical properties of cardiac muscle cells, the sinoatrial (SA) node's pacemaker function, the specialized conducting system, and the ionic mechanisms underlying each phase...
6.7K
Correlation between ECG and Cardiac Cycle01:25

Correlation between ECG and Cardiac Cycle

The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
7.7K
Propagation of Action Potentials01:23

Propagation of Action Potentials

The propagation of an action potential refers to the process by which a nerve impulse, or "action potential," travels along a neuron.
Neurons (nerve cells) have a resting membrane potential, with a slightly negative charge inside compared to outside. This is maintained by ion channels, such as sodium (Na+) and potassium (K+) channels, which control the flow of ions. When a stimulus, like a touch or a signal from another neuron, triggers the neuron, sodium channels open, allowing sodium ions to...
6.3K
Mechanism of Cardiac Arrhythmias01:28

Mechanism of Cardiac Arrhythmias

Arrhythmias are irregular heart rhythms occurring when the heart's electrical impulses become abnormal. These disturbances can lead to various symptoms, depending on their severity and the underlying cause. Some common factors contributing to arrhythmias include hypoxia, ischemia, electrolyte imbalances, excessive catecholamine exposure, drug toxicity, and muscle overstretching. Arrhythmias can be classified into two main types based on the rate and site of origin of abnormal heart rhythms.
1.0K
Conduction System of the Heart01:19

Conduction System of the Heart

Autorhythmicity is a term that refers to the heart's inherent ability to generate electrical signals and instigate muscle contractions. This self-regulating conduction system within the heart consists of two key components: the pacemaker cells and specialized conducting cells.
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
9.5K