Related Experiment Video
Updated: Aug 14, 2025

08:55
A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
17.9K
Personal dose equivalent Hp(0.07) during 68Ga-DOTA-TATE production procedures
1Department of Nuclear Physics and Radiation Safety, Faculty of Physics and Applied Informatics, University of Lodz, Pomorska 149/153, 90-236, Lodz, Poland.
Radiation and Environmental Biophysics
|January 10, 2023
Summary
Personnel in nuclear medicine departments experience significant radiation exposure when handling 68Ga-DOTA-TATE. Radiochemists face higher doses during dispensing, highlighting the need for protective measures like ring dosimeters and enhanced training.
Area of Science:
- Nuclear Medicine
- Radiation Dosimetry
- Radiopharmaceutical Handling
Background:
- Nuclear medicine personnel handle radiopharmaceuticals like 68Ga-DOTA-TATE, necessitating radiation exposure assessments.
- Understanding radiation exposure is crucial for implementing effective safety protocols in nuclear medicine departments.
Purpose of the Study:
- To quantify hand radiation exposure in nuclear medicine staff preparing and administering 68Ga-DOTA-TATE.
- To identify procedures and personnel groups with the highest radiation exposure.
- To provide recommendations for minimizing radiation exposure.
Main Methods:
- Utilized MCP-N thermoluminescent detectors for dosimetry measurements over three 1-week sessions.
- Collected 360 measurements from fingertips of radiochemists and nurses during production procedures.
- Focused on the non-dominant left hand for assessing maximum radiation exposure.
Main Results:
- The highest radiation exposure was observed on the non-dominant left hand of radiochemists and nurses.
- Radiochemists had a maximum H p(0.07)/A of 49.36 ± 4.95 mSv/GBq during dispensing.
- Nurses had a maximum H p(0.07)/A of 1.28 ± 0.13 mSv/GBq during injection, with a mean of 0.38 mSv/GBq.
Conclusions:
- The dispensing of 68Ga-DOTA-TATE accounts for a significant portion (approx. 60%) of radiochemists' fingertip exposure.
- Routine use of ring dosimeters on the non-dominant hand is recommended for both radiochemists and nurses.
- Systematic training in handling open radioactive sources is proposed to reduce exposure time and risk.