Related Experiment Video
Updated: Aug 14, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Comparison of traditional PS versus kinematically designs in primary total knee arthroplasty
Ittai Shichman1, Christian T Oakley2, Jeremiah Thomas2
1Department of Orthopedic Surgery, NYU Langone Health, 301 East 17th Street, New York, NY, 10003, USA. Ittai.Shichman@nyulangone.org.
Purpose:
Kinematically designed total knee arthroplasty (TKA) aims to restore normal kinematics by replicating the function of both cruciate ligaments. Traditional posterior-stabilized (PS) TKA designs, on the other hand, simplify knee kinematics and may improve TKA cost-effectiveness. The purpose of this study was to compare outcomes of patients who underwent primary TKA using either a traditional PS or kinematically designed TKA.
Methods:
This retrospective study examined all patients who underwent primary TKA using either a kinematically or a traditional PS designed TKA implant, with a minimum follow-up of 2 years. Patient demographics, complications, readmissions, revision rates and causes, range of motion (ROM) and patient reported outcomes (KOOS, JR) were compared between groups. Kaplan-Meier survivorship analysis was performed to estimate freedom from revision, and multivariate regression was performed to control for confounding variables.
Results:
A total of 396 TKAs [173 (43.7%) with a kinematic design, 223 (56.3%) with a traditional design] with a mean follow-up of 3.48 ± 1.51 years underwent analysis. Revision rates did not differ between groups (9.8% vs. 6.7%, p = 0.418). In Kaplan-Meier analysis at 2-year follow-up, freedom from all-cause revision (96.4% vs. 93.1%, p = 0.139) were similar between groups. The two cohorts had no significant difference in aseptic loosening at 2 years (99.6% vs. 97.1, p = 0.050) and at latest follow up (92.7% vs. 96.4%, p = 0.279). KOOS, JR scores and post-operative ROM were similar between groups.
Conclusion:
This study demonstrated similar mid-term outcomes following the use of both a kinematically designed and a traditionally designed implant in primary TKA patients.
Level Of Evidence:
Retrospective study-III.