Related Experiment Video
Updated: Aug 14, 2025

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Assessing maternal cardiac function by obstetricians: technique and reference ranges
Greggory R DeVore1, Bardo Polanco2
1Fetal Diagnostic Centers, Pasadena and Lancaster, CA; Department of Obstetrics and Gynecology, University of California, Los Angeles School of Medicine, Los Angeles, CA; Department of Obstetrics and Gynecology, Wayne State University, Detroit, MI.
Background:
A strong body of evidence has now coalesced indicating that some obstetrical syndromes may result from maladaptive responses of the maternal cardiovascular system. Longitudinal studies have shown that these changes are complex and present before the clinical recognition of preeclampsia and fetal growth restriction, suggesting that hemodynamic maladaptation may play an etiologic role in obstetrical complications. Chronic hypertension is one of the most frequent complications of pregnancy, and recent evidence suggests that control of mild hypertension in early pregnancy improves outcome. The management of chronic hypertension can be improved by understanding specific cardiovascular hemodynamic abnormalities such as increased cardiac output or increased systemic vascular resistance, which can respond to either beta or calcium channel blockers, depending on the hemodynamic findings. Evaluation of maternal cardiac function has not been previously available to obstetrical healthcare providers using diagnostic ultrasound equipment used for fetal evaluation.
Objective:
Obstetrical ultrasound machines may be configured for various probes (endovaginal, abdominal, 3D/4D, and cardiac). This study used a cardiac probe placed in the suprasternal notch to image and measure the descending aorta diameter and the velocity time integral using pulsed and continuous wave Doppler ultrasound in normal pregnant women between 11 and 39 weeks of gestation. These measurements were followed by computation of maternal left ventricular preload, afterload, contractility, and blood flow.
Study Design:
This was a prospective cross-sectional study. A total of 400 pregnant women were recruited between 11 and 39 weeks of gestation. Imaging of the maternal aortic arch was performed by placing a cardiac probe in the suprasternal notch to identify the aortic arch using 2D and color Doppler ultrasound. The end-systolic diameter of the aorta was measured at the junction of the left subclavian artery with the descending aorta, which was followed by insonation of the descending aorta to obtain the Doppler waveform. Following insonation of the descending aorta, measurements of the aortic diameter, velocity time integral, ejection time, mean pressure gradient, heart rate, maternal weight and height, and systolic and diastolic blood pressures were entered into an Excel spreadsheet to compute the following: (1) preload measurements of stroke volume, stroke volume index, and stroke work index; (2) afterload measurements of systemic vascular resistance and the potential-to-kinetic energy ratio; (3) contractility measurements of inotropy and the Smith-Madigan inotropy index; and (4) blood flow measurements of cardiac output and the cardiac output index. Fractional polynomial regression analysis was performed for each of the above measurements using gestational age as the independent variable.
Results:
The diastolic and mean arterial blood pressure decreased from 11 to 18 weeks of gestation and then increased until term. The afterload measurements demonstrated similar characteristics, as all values decreased from 11 weeks until the mid and late second trimester, after which all values increased until term. Changes in contractility demonstrated an increase from 11 weeks to 25 to 28 weeks, followed by a decline until term. Changes in blood flow demonstrated an increase from 11 to 27 weeks and then declined until term. The continuous wave Doppler values were greater than the pulsed Doppler values except for the contractility measurements. Examples of abnormal cardiac measurements were identified in pregnant patients with hypertension and fetal growth restriction. An Excel calculator was created to provide quick computation of z-score measurements and their corresponding centiles described in this study.
Conclusion:
The technique for evaluation of maternal cardiac function described in this study would allow screening of maternal left ventricular preload, afterload, contractility, and blood flow in the obstetrical clinical milieu once a cardiac probe is acquired for obstetrical ultrasound machines used for fetal evaluation. The above measurements would allow the clinician to select appropriate hypertensive medication on the basis of the results of the evaluation of the maternal left ventricle.
More Related Videos
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Mitral Stenosis IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiac Catheterization I: Pre-Procedure Overview